The Wireless TempSensor connects to Brava via Bluetooth. Recipes requiring a TempSensor give users the option to use either the Brava original wired TempSensor or the Wireless TempSensor.
Wireless TempSensor Dos and Don'ts
Do:
- After each use, allow the TempSensor to cool down, give it a nice cleaning, and place it back on the charging dock when Dry to ensure it's charged for your next use.
Don't:
- Put a hot TempSensor into any water right after cooking.
- Leave a hot TempSensor on a hot metal tray.
- Leave the Tempsensor in the brava after your cook is completed
Before Using the Wireless TempSensor for the First Time
- Place the TempSensor onto the charging dock. Insert the pointy tip of the TempSensor into the hole on the side of the charging dock with the LED light. Then gently secure the ceramic handle on the opposite side until you hear a click to ensure a snug fit.
Connect the included charging cord to the TempSensor Charging dock and plug in for at least 1 Hour before using. The LED lights will cycle through while charging.
- Use a slightly damp cloth to thoroughly wipe the TempSensor.
- IMPORTANT: Check that your Brava is on the latest software.
Using the Wireless TempSensor for the First Time
Pairing or Connecting the Wireless TempSensor to Brava
Once you select a recipe that requires the TempSensor, the Brava screen will guide you through the pairing process to connect the Wireless TempSensor to your Brava.
- Select a recipe that requires the TempSensor, follow the setup steps on the screen below. Tap on the Connect button under the Use Wireless TempSensor option. Keep the TempSensor docked in the charger.
- You may need to click the button on the charging dock to activate pairing. Pairing could take up to 60 seconds.
- When below screen comes on, take the Wireless TempSensor out of the charger.
- Once the Brava screen indicates the Wireless TempSensor is connected to the Brava, you can insert the TempSensor into your protein.
NOTE
An alternative way to pair your Wireless TempSensor to Brava for the first time is to click on the Bluetooth icon on the upper right corner of the home screen. Follow the onscreen instructions. When the below screen appears, tap on Ready to Pair.
Cooking with the Wireless TempSensor
- Insert the entire probe horizontally into the middle and/or thickest part of the protein; make sure the probe is parallel to the tray and not angled toward the lamps or touching the tray. Do not leave any part of the metal probe exposed to avoid heat damage.
- Just like the original wired TempSensor, you can monitor the protein temperature on the Brava screen or on the Brava app.
- Once the cook is complete, use a piece of paper towel or other heat protection to pull the wireless TempSensor out of the protein. The handle is HOT.
Using the Wireless TempSensor on Subsequent Cooks
The TempSensor stays paired with the Brava after the initial pairing. There are 2 ways to wake the TempSensor. The first method is faster.
Method 1. Go to the Brava home screen. Make sure the TempSensor is docked in the charger. Press the button on the charger, then remove the TempSensor from the charger. Within a few seconds the TempSensor is awakened and ready for use.
Method 2. Go the recipe you are using, navigate to the TempSensor connection screen, click on Connect under the Use Wireless TempSensor. With the TempSensor docked in the charger, press the button on the charger, then remove the TempSensor and wait for confirmation the TempSensor is connected.
After Using the Wireless TempSensor
Cleaning
- Let the Wireless TempSensor cool down before cleaning it.
- Clean the Wireless TempSensor using a sponge, soap, and warm running water. Do not use anything abrasive to scrub the black ceramic handle. Do not soak the TempSensor in water and do not wash it in the dishwasher.
- Never place a wet TempSensor on the charging dock; this will damage the charging prongs and cause it to stop holding a charge over time.
Storage
- Store the Wireless TempSensor in the charging dock (this also keeps your TempSensor charged, as long as the charging dock has a battery). Make sure it is clean and dry before docking.
Charging
Charging Dock:
- The LED on the charging dock will flash green while it's charging
- The LED will turn to solid green once the charging dock is fully charged
- Please note that the LED light will rotate through all light statuses while charging
- When the Charging dock is fully charged, it can remain active for over 15 hours.
TempSensor:
- Insert the Tempsensor into the charging dock to charge automatically. The LED will flash green until the battery is full.
- When fully charged, the Tempsensor can remain active for over 50 hours.
Warning Messages During Cooks
Due to the intense heat from the lamps, it is important that the electronic sensors on the TempSensor are shielded from it as much as possible.
Your Brava may pause during a cook when a certain part of the TempSensor gets too hot. The warning message will provide information on adjustment needed to ensure the TempSensor does not get damaged. Once the adjustment has been made, push the green cook button to continue the cook. There is no need to start the cook over.
*Best practice: is to have the black ceramic handle on the left side of the Brava tray and not in the direct middle of the tray.
|
Action: Ensure the black handle is not touching the tray or directly under the lamps in the middle of the tray. |
|
|
Action: Check the ensure the probe needle is inserted all the way into the protein. |
|
|
Action: The probe may be inserted at an angle, causing the tip of the probe to touch the tray. Reinsert the probe horizontally, parallel to the tray. |
|
|
Action: Remove the Wireless TempSensor from the hot metal tray and put it on a room temp surface to cool down. |
LED Light on the Charger
Solid Green: TempSensor is Fully charged (TempSensor is in the charging dock). / Charging Dock is fully charged (Only when plugged in).
Flashing Green: TempSensor Battery is Charging (only when placed on the Charging Dock). / Charging Dock is charging(only when plugged into the proper power source)
White/Blue: Pairing Bluetooth
Red: Low Battery (Tempsensor and/or Charging Dock)
Brava Screen Icons
Seen on the upper right corner of the main screen. Indicates Brava is ready to pair or the Wireless TempSensor is paired but asleep. If you have previously paired the Wireless TempSensor, simply press the button on the charger with the TempSensor docked to wake it up (reconnect). The Bluetooth indicator should turn to
once connected.
Seen on the upper right corner of the main screen. Indicates Brava is connected to the Wireless TempSensor.
Seen while setting up the Wireless TempSensor when using a recipe. The battery image indicates the amount of charge for the Wireless TempSensor. The image shown here indicates the TempSensor is fully charged.
Comments
Please sign in to leave a comment.